描述
Physical Parameters
Color: Various colors
Gloss: High gloss, Semi-gloss
Standard Film Thickness:
Wet Film Thickness (WFT): 95 μm
Dry Film Thickness (DFT): 40 μm
Theoretical Spreading Rate: Approx. 7.5 ㎡/kg
Flash Point: Non-flammable
Density: Approx. 1.3 g/cm³
Application Instructions
Mixing Ratio: Two-component (mix Part A and Part B thoroughly in their specified proportions prior to use)
Thinner: Deionized water
Cleaning Solvent: Tap water
Application Methods: Airless Spray, Conventional Air Spray, or Brush/Roller Coating.
Spraying Parameters
| Parameter | Airless Spray | Conventional Air Spray | Brush / Roller |
| Nozzle/Tip Size | (Graco) 163T-619/621 | 1.8 ~ 2.5 mm | — |
| Fluid Pressure (MPa) | 15 ~ 35 | 0.3 ~ 0.4 | — |
| Thinning Ratio | 0 ~ 5% | 0 ~ 15% | 0 ~ 5% |
Note: Airless and conventional air spray data are for reference only and can be adjusted based on onsite conditions during practical application.
Drying Time & Overcoating Interval
| Substrate Temp. (°C) | Surface Dry (min) | Hard Dry (h) | Min. Overcoating Interval (h) | Max. Overcoating Interval |
| 5 | 100 | 24 | 12 | No limitation |
| 15 | 50 | 12 | 8 | No limitation |
| 20 | 30 | 8 | 6 | No limitation |
| 30 | 15 | 5 | 3 | No limitation |
Surface Preparation
Prior to application, ensure that the preceding primer or intermediate coat is completely dry, clean, and free of oil stains, dust, salts, and other impurities. The underlying paint film must be smooth, firm, and free of loose flaking.
When overcoating existing coatings, the old paint layer must be thoroughly abraded and roughened to eliminate chalked or aged areas. Clean off all dust before application to guarantee robust intercoat adhesion.
Application Conditions
Temperature & Humidity: The application temperature range is 5 ~ 35°C with a relative humidity (RH) below 80%. The substrate surface temperature must be at least 3°C above the dew point.
Constraints: Application is strictly prohibited in condensing environments, heavy fog, or high humidity to prevent film defects like whitening or loss of gloss. Do not apply outdoors during rain, snow, or severe wind and sandstorms.
Sub-Zero Warning: Construction and storage ambient temperatures must never fall below 0°C. Freezing temperatures will break the emulsion phase and ruin the coating.
Coating System Compatibility
Preceding Coats: Waterborne Zinc-Rich Primer, Waterborne Epoxy Primer, Epoxy MIO (Micaceous Iron Oxide) Intermediate Paint, or Waterborne Acrylic Primer.
System Constraint: Do not pair directly with aggressive, strong solvent-borne coatings to prevent lifting or wrinkling (“paint biting”) of the undercoat.
Packaging Specifications
24 kg / set (Base Paint Part A: 21 kg + Curing Agent Part B: 3 kg)
Storage
Store this product in a cool, dry, and well-ventilated indoor warehouse, away from heat sources. Ensure protection against freezing and direct sunlight.
The base paint and curing agent must be stored separately. Maintain the storage temperature range between 5°C and 30°C. The shelf life is 12 months under standard room temperature conditions.
Safety Precautions
This product is a waterborne coating and is non-flammable and non-explosive. Maintain excellent ventilation throughout the application site.
Applicators must wear appropriate personal protective equipment (PPE), including dust/mist masks, safety goggles, and solvent-resistant gloves. Avoid inhaling paint mist.
If paint contacts the skin, wash thoroughly with soap and water. If it splashes accidentally into the eyes, rinse immediately with a large volume of water and seek immediate medical attention. Clean all tools with tap water immediately after use.
Disclaimer
The protective performance of any coating largely depends on application factors. Surface preparation and film thickness will directly affect the service life of the coating. Users must ensure compliance with the specified application conditions.
The data provided in this manual are theoretical values or derived from experimental accumulation. Some data may change due to continuous product improvements without prior notice.
When our company’s technical personnel are not present at the application site, the company is solely liable for the quality of the coating product itself.